Quadrupole ICP mass spectrometer

Model
ICP質量分析計
Manufacturer
Perkin Elmer
Specification
NexION 350D, Perkin Elmer. Was installed in 2015.A quadrupole ICP-MS with a universal cell between the ion lens and the quadrupole mass separator. In reaction mode, molecular ions react with reactive gases (such as NH3) and are removed among the ions that have passed through the ion lens. On the other hand, the target atomic ions enter the mass separation section without being affected by the reaction gas, are separated by the mass-to-charge ratio (m/z) and then reach the detection section. Therefore, the detection limit for Fe, Ca, etc., which are subject to interference from molecular ions, is significantly lower.The simultaneous multi-element quantification of approximately 70 elements is possible at the ppt (10-12) level.This device is used for monitoring and researching heavy metals in experiment discharge in the Uji area.
Location
Institute for Chemical Research Uji District Wastewater Treatment Facility
Installation Year
2015
Overview

NexION 350D, Perkin Elmer. Was installed in 2015.
A quadrupole ICP-MS with a universal cell between the ion lens and the quadrupole mass separator. In reaction mode, molecular ions react with reactive gases (such as NH3) and are removed among the ions that have passed through the ion lens. On the other hand, the target atomic ions enter the mass separation section without being affected by the reaction gas, are separated by the mass-to-charge ratio (m/z) and then reach the detection section. Therefore, the detection limit for Fe, Ca, etc., which are subject to interference from molecular ions, is significantly lower.
The simultaneous multi-element quantification of approximately 70 elements is possible at the ppt (10-12) level.
This device is used for monitoring and researching heavy metals in experiment discharge in the Uji area.

Responsible department

Uji District Wastewater Treatment Facility

Available Users

Kyoto University,Other Research,Companies, etc.
After consulting about the usage details, the user basically operates the device themselves and acquires the data under the guidance of the person in charge, if available.

Notes

If you wish to use the device, please get in touch with the person in charge by e-mail or phone.

Usage rules

* Rules of use apply to the “Double convergence type high-resolution ICP mass analyzer.” For details, please refer to the following address.
http://chem-eqnet.ims.ac.jp/

Inquiries

Institute for Chemical Reasearch Division of Environmental Chemistry Hydrospheric Environment Analytical Chemistry (Contact:Sohrin )
TEL
0774-38-3100
MAIL
sohrin*scl.kyotyo-u.ac.jp
※Please change 「*」 to 「@」 and send.

USACO website
TOP